  • Premium disposable fold flat respirator for easy storage, donning and doffing
  • Secure, metal-free harness system with colour coded textile elastic for easy identification of FFP level
  • Soft, flexible and adjustable nose bridge for increased fit factor and comfort
  • Multilayer electrostatic filter media for high-performing filtration with low breathing resistance
  • Full-width internal faceseal, made from soft touch PVC for high comfort
  • Ergonomic design for a secure fit on a wide range of face shapes
  • High flow exhalation valve for low breathing resistance, colour-coded for easy identification of FFP level
  • Contoured noseseal for high compatibility with other types of PPE
  • All variants complaint to EN 149:2001+A1:2009. Unvalved variant compliant to EN 14683:2019 for use in healthcare
  • Latex-free and low-linting for use in a wide range of environments
  • UK designed, developed and manufactured

Certifications

CAT III

Options




Applications

Battery Manufacturing
Civil Engineering
Disease and Infection Control
General Medical Practice
Metal Fabrication Work
Metal Forging and Processing
Pharmacists
Wards

Further Information

The 4500 Series is the newest addition to Skytec’s range of premium respirators. Featuring premium European-Made filter media across valved and unvalved variants, the 4500 Series range provides low breathing resistance and excellent Face Fit Factor.

Available Options

Product Code Size Colour Width Length Height Weight
ASRAPL200AZ One-Size
White
105mm 180mm 260mm 218g

Product Specifics

Master SKUASRAPL300AV
Series4500
Filter Media MaterialNon-Woven Textile
Inner Cover MaterialPolypropylene
Headstrap MaterialLatex-Free Elastane, Polyester, Textile Elastic
Outer Cover MaterialPolypropylene
Nosefoam MaterialPolyethylene Foam

Certifications

CE
Cat LevelIII
EN 149:2001 + A1:2009 FFP2 NR

EN 149:2001

Class FFP2
Disposable

Options

Selected Option Specifics (ASRAPL200AZ)

SKUASRAPL200AZ
SizeOne-Size
Main Colour
White
Shelf Life5Years

Storage Conditions

Minimum Temperature-5°C
Maximum Temperature35°C
Humidity<70%

Unit Dimensions

Unit Weight218g
Unit Width105mm
Unit Length180mm
Unit Height260mm

Packaging

Items per Pack10
Pack height26cm
Pack width10.5cm
Pack weight0.22kg
Items per Case120
Case height36.9cm
Case width33cm
Case length52.4cm
Case weight3.61kg
Packs per Carton12
Units per Pallet2880
Plastic Weight1g

Product Selector Guidance Chart

Option Assigned Protection (APF) Oil/Water Based Particulates Non-Toxic Dusts Fine Toxic Dusts/Mists/Fumes Very Fine Toxic Dusts/Mists/Fumes Metal Fume
ASRAPL200AZ 10 Recommended Recommended Recommended

Parts Dimensions

Part Width Length Height
Respirator 85 mm 210 mm 20 mm
Recommendations for Use
USER INSTRUCTIONS: Use only in accordance with these instructions, as incorrect use could result in danger to life or health. Fit according to instructions BEFORE entering the contaminated area. Discard safely after use or replace with a new respirator if: • Excessive clogging of the respirator causes breathing difficulty or discomfort • If the respirator becomes damaged • The respirator has been worn for 8 hours. Do not use in oxygen deficient, (less than 19%), explosive atmospheres or confined spaces where gases or aerosols may accumulate and the concentration of contaminant is immediately dangerous to life or health, (over the IDLH value). Leave the contaminated area if: • The respirator is damaged • You become dizzy or have difficulty breathing • You become irritated or other distress occurs • You become uncertain of the nature and/or concentration of contaminant. WARNING: • As facial hair reduces the protection offered it is recommended that these respirators are used by clean shaven personnel only • Do not use for protection against gases • Single shift use only • Do not remove whilst in contaminated area.
EC Compliance
Type-Examination Certificate [Module B] issued by: CE - CCQS Certification Services Limited - Block 1 Blanchardstown Corporate Park, Ballycoolin Road, Blanchardstown, Dublin 15 D15 AKK1, Dublin, Ireland [NB No. 2834] UKCA - CCQS UK Ltd - Level 2 5 Harbour Exchange Square, London, E14 9GE, United Kingdom [AB No. 1105] Authorised Representative [EU]: Globus EMEA Ltd, 51 Dawson Street, Dublin, D02 AN25, Ireland