ASF-2
FFP2 Disposable Fold-Flat Respirator
Product Features
- Lightweight, fold-flat respirator
- Flexible nose bridge
- Inner seal around the nose area for an effective fit
- Electrostatic filter media
- Conforms to EN 149:2001+A1:2009 FFP2 NR
- Available in two size options, (regular - AFS and small - ASFS).
- Ideal to fit a wide range of face shapes
- Adjustable loop-through straps
- Latex Free
Certifications
CAT III
Options
Product Resources
Applications
Masonry and Brickwork
Chemical Handling and Containment
Disease and Infection Control
Woodwork and Fabrication
Plastering
Features
Made in the UK
Further Information
The AlphaFold+ is a vertical fold flat disposable respirator designed with an inner face seal, adjustable straps and two size options to offer an excellent fit for all face shapes.
Available Options
Product Code | Size | Colour | Weight |
---|---|---|---|
ASRASF200AD | S |
White
|
1.38g |
ASRASF200AF | M |
White
|
1.38g |
Product Specifics
Master SKU | ASRASF200 |
---|---|
Series | Alphafold+ |
Filter Media Material | Non-Woven Textile |
Inner Cover Material | Polypropylene |
Headstrap Material | Latex-Free Elastane, Polyester, Textile Elastic |
Outer Cover Material | Polypropylene |
Nosefoam Material | Polyethylene Foam |
Certifications
CE | ✓ |
---|---|
Cat Level | III |
EN 149:2001 + A1:2009 | FFP2 NR |
EN 149:2001
Class | FFP2 |
---|---|
Disposable | ✓ |
Options
Selected Option Specifics (ASRASF200AD) (ASRASF200AF)
SKU | ASRASF200AD |
---|---|
Size | S |
Main Colour |
White
|
Shelf Life | 5Years |
Selected Option Specifics (ASRASF200AD) (ASRASF200AF)
SKU | ASRASF200AF |
---|---|
Size | M |
Main Colour |
White
|
Shelf Life | 5Years |
Storage Conditions
Minimum Temperature | -5°C |
---|---|
Maximum Temperature | 35°C |
Humidity | <70% |
Unit Dimensions
Unit Weight | 1.38g |
---|
Unit Dimensions
Unit Weight | 1.38g |
---|
Packaging
Items per Pack | 20 |
---|---|
Items per Case | 240 |
Case height | 44cm |
Case width | 24cm |
Case length | 54cm |
Packs per Carton | 12 |
Units per Pallet | 5760 |
Packaging
Items per Pack | 20 |
---|---|
Items per Case | 240 |
Case height | 44cm |
Case width | 24cm |
Case length | 54cm |
Packs per Carton | 12 |
Units per Pallet | 5760 |
Product Selector Guidance Chart
Option | Assigned Protection (APF) | Oil/Water Based Particulates | Non-Toxic Dusts | Fine Toxic Dusts/Mists/Fumes | Very Fine Toxic Dusts/Mists/Fumes | Metal Fume |
---|---|---|---|---|---|---|
ASRASF200AD | 10 | Recommended | Recommended | Recommended | ||
ASRASF200AF | 10 | Recommended | Recommended | Recommended |
Parts Dimensions
Part | Width | Length | Height |
---|---|---|---|
Respirator | 120 mm | 155 mm | 10 mm |
Part | Width | Length | Height |
---|---|---|---|
Respirator | 125 mm | 160 mm | 10 mm |
Recommendations for Use
USER INSTRUCTIONS:
Use only in accordance with these instructions, as incorrect use could result in danger to
life or health. Fit according to instructions BEFORE entering the contaminated area.
Discard safely after use or replace with a new respirator if:
• Excessive clogging of the respirator causes breathing difficulty or discomfort
• If the respirator becomes damaged
• The respirator has been worn for 8 hours.
Do not use in oxygen deficient, (less than 19%), explosive atmospheres or confined
spaces where gases or aerosols may accumulate and the concentration of contaminant
is immediately dangerous to life or health, (over the IDLH value).
Leave the contaminated area if:
• The respirator is damaged
• You become dizzy or have difficulty breathing
• You become irritated or other distress occurs
• You become uncertain of the nature and/or concentration of contaminant.
WARNING:
• As facial hair reduces the protection offered it is recommended that these respirators
are used by clean shaven personnel only
• Do not use for protection against gases
• Single shift use only
• Do not remove whilst in contaminated area.
Recommendations for Use
USER INSTRUCTIONS:
Use only in accordance with these instructions, as incorrect use could result in danger to
life or health. Fit according to instructions BEFORE entering the contaminated area.
Discard safely after use or replace with a new respirator if:
• Excessive clogging of the respirator causes breathing difficulty or discomfort
• If the respirator becomes damaged
• The respirator has been worn for 8 hours.
Do not use in oxygen deficient, (less than 19%), explosive atmospheres or confined
spaces where gases or aerosols may accumulate and the concentration of contaminant
is immediately dangerous to life or health, (over the IDLH value).
Leave the contaminated area if:
• The respirator is damaged
• You become dizzy or have difficulty breathing
• You become irritated or other distress occurs
• You become uncertain of the nature and/or concentration of contaminant.
WARNING:
• As facial hair reduces the protection offered it is recommended that these respirators
are used by clean shaven personnel only
• Do not use for protection against gases
• Single shift use only
• Do not remove whilst in contaminated area.
EC Compliance
Economic Operator [EU]: Globus EMEA Ltd., 51 Dawson Street, Dublin, D02 AN25, Ireland.
Product conforms to the requirement of: UK Regulation 2016/425 on PPE, brought into UK Law and amended & Regulation (EU) 2016/425 of the European Parliament and of the Council as Personal Protective Equipment (PPE).
Type-Examination, (Module B), Certificates issued by:
UK - CCQS UK Ltd., Level 2, 5 Harbour Exchange Square, London, E14 9GE, UK [A.B. No. 1105].
EU - CCQS Certification Services Limited, Block 1 Blanchardstown Corporate Park, Ballycoolin Road, Blanchardstown, Dublin D155 AKK1, Ireland [N.B. No. 2834].
PPE is subject to the conformity assessment procedure, conformity to type based on Quality Assurance of the production process, (Module D), under the surveillance of the Approved/Notified Body(-ies):
UK - SGS UK Ltd., Rossmore Business Park, Ellesmere Port, Cheshire, CH65 3EN, UK. [A.B. No. 0120].
EU - SGS Fimko Oy, Takomtie 8, FI-00380, Helsinki, Finland. [N.B. No. 0598].