Skytec 4520 Alpha 3 Panel FFP2 Respirator
Skytec 4520 Alpha 3 Panel FFP2 Respirator
Skytec 4520 Alpha 3 Panel FFP2 Respirator
Skytec 4520 Alpha 3 Panel FFP2 Respirator

4520

Introducing the latest innovation from Skytec, the 4500 Series of 3-panel fold-flat respirators. Designed, developed and manufactured in the UK from premium UK-made filter media. Both valved and unvalved variants feature unique features with high-quality finish to enhance user acceptance.

Skytec 4520 Alpha 3 Panel FFP2 Respirator mobile image
Skytec 4520 Alpha 3 Panel FFP2 Respirator mobile image
Skytec 4520 Alpha 3 Panel FFP2 Respirator mobile image
Skytec 4520 Alpha 3 Panel FFP2 Respirator mobile image

Product Features

  • Premium disposable fold flat respirator for easy storage, donning, and doffing
  • Secure, metal-free harness system with colour-coded textile elastic for easy identification of FFP level
  • Optimised head harness provides high face fit pass rates across various face shapes
  • Structured panels provide additional strength in maintaining the mask shape structure
  • Soft, flexible, and adjustable nose bridge for increased fit factor and comfort
  • Multilayer electrostatic filter media for high-performing filtration with low breathing resistance
  • Full-width internal faceseal, made from soft touch PVC for high comfort
  • Ergonomic faceseal shape for a secure fit to a wide range of face shapes
  • Contoured noseseal for high compatibility with other types of PPE
  • Unvalved variant compliant to EN 14683 medical devices for use in healthcare
  • Latex and lint-free for use in a wide range of environments
  • UK designed, developed, and manufactured

Certifications

CAT III

Options




Applications

Battery Manufacturing
Civil Engineering
Laboratory Analysis
Metal Fabrication Work
Metal Forging and Processing

Further Information

The 4500 Series is the newest addition to Skytec's range of premium respirators. Drawing on DNA from high performance products such as 3030V, Alpha S and Alpha Sentinel, the 4500 Series been designed, developed and manufactured for optimum protection against particulate based hazards. Testament to Skytec's continuous dedication to innovation, the 4500 instils confidence in the wearer, through an intelligently designed set of features that fit a wide range of faces, affording comfort, protection and performance to the wearer. Featuring premium UK Made filter media across valved and unvalved variants, the 4500 Series range provides low breathing resistance and excellent fit factor.

Available Options

Product Code Size Colour Weight
ASRAPL201AZ One-Size
White
10.1g

Product Specifics

Master SKUASRAPL201A
Filter Media MaterialNon-Woven Textile
Inner Cover MaterialPolypropylene
Headstrap MaterialLatex-Free Elastane, Polyester, Textile Elastic
Outer Cover MaterialPolypropylene
Nosefoam MaterialPolyethylene Foam

Certifications

CE
Cat LevelIII
UKCA
EN 149:2001 + A1:2009 FFP2 NR
EN 14683:2019 Type IIR
EN 136:1998 Class 1

EN 149:2001

Class FFP2
Disposable

Options

Selected Option Specifics (ASRAPL201AZ)

SKUASRAPL201AZ
SizeOne-Size
Main Colour
White
Shelf Life5Years

Storage Conditions

Minimum Temperature-5°C
Maximum Temperature35°C
Humidity<70%

Unit Dimensions

Unit Weight10.1g

Packaging

Items per Pack20
Pack height25.5cm
Pack width10.5cm
Pack length18cm
Items per Case240
Case height36.9cm
Case width33cm
Case length52.4cm
Case weight4.73kg
Units per Pallet5760

Product Selector Guidance Chart

Option Assigned Protection (APF) Oil/Water Based Particulates Non-Toxic Dusts Fine Toxic Dusts/Mists/Fumes Very Fine Toxic Dusts/Mists/Fumes Metal Fume
ASRAPL201AZ 10 Recommended Recommended Recommended

Parts Dimensions

Part Width Length Height
Respirator 85 mm 210 mm 20 mm
Recommendations for Use
USER INSTRUCTIONS: Use only in accordance with these instructions, as incorrect use could result in danger to life or health. Fit according to instructions BEFORE entering the contaminated area. Discard safely after use or replace with a new respirator if: • Excessive clogging of the respirator causes breathing difficulty or discomfort • If the respirator becomes damaged • The respirator has been worn for 8 hours. Do not use in oxygen deficient, (less than 19%), explosive atmospheres or confined spaces where gases or aerosols may accumulate and the concentration of contaminant is immediately dangerous to life or health, (over the IDLH value). Leave the contaminated area if: • The respirator is damaged • You become dizzy or have difficulty breathing • You become irritated or other distress occurs • You become uncertain of the nature and/or concentration of contaminant. WARNING: • As facial hair reduces the protection offered it is recommended that these respirators are used by clean shaven personnel only • Do not use for protection against gases • Single shift use only • Do not remove whilst in contaminated area.
EC Compliance
Economic Operator [EU]: Globus EMEA Ltd., 51 Dawson Street, Dublin, D02 AN25, Ireland. Product conforms to the requirement of: UK Regulation 2016/425 on PPE, brought into UK Law and amended & Regulation (EU) 2016/425 of the European Parliament and of the Council as Personal Protective Equipment (PPE). Type-Examination, (Module B), Certificates issued by: UK - CCQS UK Ltd., Level 2, 5 Harbour Exchange Square, London, E14 9GE, UK. [A.B. No. 1105]. EU - CCQS Certification Services Ltd., Block 1 Blanchardstown Corporate Park, Ballycoolin Road, Blanchardstown, Dublin D155 AKK1, Ireland. [N.B. No. 2834]. PPE is subject to the conformity assessment procedure, conformity to type based on Quality Assurances of the production process, (Module D), under the surveillance of the Approved/Notified Body(ies): UK - SGS UK Ltd., Rossmore Business Park, Ellesmere Port, Cheshire, CH65 3EN, UK. [A.B. No. 0120]. EU - SGS Fimko Oy, Takomtie 8, FI-00380, Helsinki, Finland. [N.B. No. 0598].
Compare 3 products selected